Vedere la pagina 9
DataPage Lite (USA) Desktop UHF Radio Paging System
DPUSAlite 10/01 10 Issue 1
Problems and Fault Finding
Check that there is power at the mains socket.
Check that the pagers are at least 3 meters from the transmitter and aerial. Under certain conditions it is
possible to flood the pager receivers and corrupt the data received.
Check that the pagers have the battery installed with the correct polarity and are correctly powered up.
Check that the aerial is correctly installed.
Check the Base ID on the password menu matches the system data. Check the transmission baud rate matches
the system data.